Type LST
Safety isolating transformer
for halogen lamps

Execution in accordance to VDE 0551,
EN 60742, IEC 742, VDE 0710 Teil 14
Protective class II
Protective type IP 20
Thermal class E
Nominal ambient temperature ta 40°C

Input voltage: 230 VAC
Output voltage: 11,5 VAC
Frequency: 50/60Hz
Non. inherently short-circuit
Test voltage PRI - SEC 4,5 kVAC
Two chamber winding
Resin moulded



Safety isolating transformers, encapsuled in resin for supplying 12V- halogen lamps.
The transformers are constructed for an input of 230VAC. The nominal voltage of the
halogen lamps does not exceed, even with usual excess voltage. This means:
longer life of your halogen lamps.
For protection against inadmissible current load and short-circuit a changeable fuse
and a self-reseting thermal cut-out is incorporated.
The input has a 1,5m mains lead with a mounted Euro-plug. The output has a terminal,
or wires of 1m length.
Suitable for built-in mounting on furniture or in lowered cellings.
With dimmer suitibility for regulation of the brightness.



type measure (mm) weight
A B C D E kg
LST 20/K
LST 35/K
LST 50/K
LST 60/K
LST 75/K
LST 100/K
LST 150/K
LST 200/K
LST 300/K
93
93
105
105
112
112
134
134
177
61
61
70
70
75
75
87
87
107
49
60
59
59
64
77
85
99
109
77
77
90
90
97
97
115
115
150
47
47
58
58
60
60
70
70
85
0,73
1,00
1,30
1,35
1,70
2,28
3,28
3,88
5,10

 



type measure (mm) weight
A B C D E kg
LST 20/L
LST 35/L
LST 50/L
LST 60/L
LST 75/L
LST 100/L
LST 150/L
LST 200/L
LST 300/L
87
87
100
100
108
108
130
130
177
61
61
70
70
75
75
87
87
107
49
60
59
59
64
77
85
99
109
77
77
90
90
97
97
115
115
150
47
47
58
58
60
60
70
70
85
0,73
1,00
1,30
1,35
1,70
2,28
3,28
3,88
5,10



type lamp power Output current efficiency
K/L W A ca. %
LST 20
LST 35
LST 50
LST 60
LST 75
LST 100
LST 150
LST 200
LST 300
20
35
50
60
75
100 ... 105
150
200
300
1,60
2,80
4,00
4,80
6,00
8,00 ... 8,40
12,00
16,00
24,80
75
82
83
83
84
86
88
90
92